GENERAL DESCRIPTION

VENUS
AUTOMATED CLINICAL CHEMISTRY RANDOM ACCESS ANALYSER
CODE RM5000

SYSTEM OVERVIEW

VENUS
AUTOMATED CLINICAL CHEMISTRY RANDOM ACCESS ANALYSER
CODE RM5500

Biochemical Systems International Srl reserves the right to change specifications without prior notice.

TECHNICAL FEATURES

VENUS
AUTOMATED CLINICAL CHEMISTRY RANDOM ACCESS ANALYSER

MEASURING SYSTEM
Operating mode Absorbance, End-Point (Up to 8 standards), Fixed Time, Kinetic, Differential, Turbidimetric (photometric reading)
Throughput Up to 180 tests/hour (mono or bireagent); 300 te with ISE
Light source 12V 20W halogene lamp
Spectral Range 320-690 nm
Filter Wavelength 340, 405, 450, 492, 505, 546, 578, 630 nm, two free position
Optics Solid state detectors,static interferential filters
Mode True Random Access, Walk Away Analyser, Continuous sample loading,
Direct reading in the reaction wells at all the wavelength simultaneously
SAMPLE HANDLING
Sample number 75 positions including samples, calibrators, controls, blank
Sample container 1.5-50µl (0.25µl step)
Specimen Serum, Plasma, CSF, Urine, Blood
Priority levels STAT, Pediatric, Normal, Suspended, Rerun
Hardware Dedicated arm, dedicated syringe (500 uL), level sensor on needle, motorized tray
Barcode Optional Manual for all the samples during positioning
Automatic dilution Pre and post dilution performed automatically or on request
Worklists Up to 5 worklists (STAT, pediatric, suspended, rerun, pediatric)
REAGENT HANDLING
Reagent tray 27 bottles for R1 (50 mL), cooled 9 indipendent bottles (10 mL) for R2, cooled
Cooling system Peltier based convective air forced, integrated for both R1 and R2, stand-by button with indipendent switch
Reagent volume R1 and R2: 20 to 500 µl (0.1 µl steps)
R1 hardware 1000 uL indipendent syringe, dedicated arm, preheating system on needle, liquid detection on needle,
cooling system on carousel, motorized tray
R2 hardware 1000 uL indipendent syringe, dedicated arm, preheating system on needle, liquid detection on needle,
cooling system on tray, static tray
Barcode Optional, manual for all the reagents during positioning
REACTION TRAY
Number of wells 60 optic bionex plastic reaction cells
Reading volume 180 to 500 uL
Well temperature 37 °C; ± 0.1 °C, controlled by Peltier and microprocessor
WASHING SYSTEM
Reaction Wells 11 steps washing station
Waste Automatic separation of concentrated and diluted waste
R1 needle Automatic internal and external washing by dedicated wash station
R2 needle Automatic internal and external washing by dedicated wash station
Sample needle Automatic internal and external washing by dedicated wash station
Alarm for diluted waste full By sensor, runtime
Alarm for concentrated waste full By sensor, runtime
Alarm for wash solution dry By sensor, runtime
SOFTWARE/INTERFACE/OTHER
Personal Computer External. Minimum requirement: CPU 3.0 GHz, 1024 MB RAM, Microsoft Windows XP or 2000 ®,
1 RS-232, 1 LPT, USB
Printer External
Communication USB or RS-232
Power supply AC 110-230V, autosense, 50/60 Hz
Power consumption AC 110-230V, autosense, 50/60 Hz
Working temperature 15 - 30 °C
Patient entry By workplan or barcode
Quality control Levey-Jennings and Westgaard rules
Other features Run time monitor, continuous sample loading, full spectrum display

Biochemical Systems International Srl reserves the right to change specifications without prior notice.